Model shown 70 Gallon
with solenoid valve feed |
An extensive range of reliable high quality
Water Heaters, especially designed for use in farm dairies.
- Stainless
Steel Outer Cabinet
- Stainless Steel Water Tank
- Very High
Quality Insulation for maximum economy - essential in these days
of never-ending electricity price increases!
- Digital Controller to maximise
electricity savings by heating during "economy-7" periods
- Dual-Outlets (70 gallon and
larger) allow for two washes between re-heat cycles
- Stainless Steel Fittings
- Stainless Steel Immersion
heater element (Incoloy)
- Also available with side
mounted header tank
|
MASSIVE
SAVINGS IN ELECTRICITY COSTS!
Our heaters
are equipped to heat up during the "off-peak" period,
saving up to 75% of electricity costs. |
Also available
in
wall-mounted versions |
|
Being of all-stainless-steel contruction,
Cotswold Dairy Water Heaters are guaranteed against corrosion
and can be relied upon to give very long service. The fully
insulated internal tanks are fitted with a 1¼"
BSP stainless steel drain outlet (1½" BSP on 200
gallon and larger sizes), stainless-steel outlets and overflows,
and stainless steel elements. The inner tank is square,
ensuring maximum capacity in minimum space.
Most models include a time clock,
graduated in 15 minute intervals, as well as manual over-ride
button and indicator lamps. A thermometer calibrated in centigrade
degrees is also fitted. An automatic vacuum switch ensures
that no cold water can enter whilst the farm vacuum pump is in
operation.
Economy models are available, built to
the same high standards but with ball-valve feed in place of
the solenoid valve. |
MODEL RANGE
|
WH21e (economy) WH30e (economy)
WH40e (economy)
WH30
WH40
WH50
WH60
WH70
WH80
WH100
WH120
WH135
WH150
WH200
WH30DX
WH40DX
3-Phase models available
Side-Mounted
Header Tank
Chiller / Ice bank
Heat-Recovery
models |
Economy 24 gallon / 110 litre
(3Kw heater, ball valve)
Economy 30 gallon / 137 litre (3kw heater, ball valve)
Economy 40 gallon / 182 litre (3kw heater, ball valve)
Standard 30 gallon / 137 litre 3kw heater element
Standard 40 gallon / 182 litre 4.8kw heater element
Standard 50 gallon / 228 litre 4.8kw heater element
Standard 60 gallon / 273 litre 4.8kw / 6kw heater element
Standard 70 gallon / 319 litre 6kw heater element
Standard 80 gallon / 364 litre 6kw heater element
Standard 100 gallon / 319 litre 6kw / 9kw heater element
Standard 120 gallon / 546 litre 2 x 6kw heater elements
Standard 135 gallon / 615 litre 2 x 6kw heater elements
Standard 150 gallon / 683 litre 2 x 6kw heater elements
Standard 200 gallon / 900 litre 2 x 9kw heater elements
30 gallon / 137 litre with
Brass pump/timer, 3kw element
40 gallon / 182 litre with Brass pump/timer, 3kw element
Off-peak models with twin water outlets and dual time clock are
available
Most standard models can now
be supplied with a side mounted header tank (as pictured
below), at no extra cost.
All models can be manufactured
with internally-mounted stainless steel coils to allow recovery
and re-use of the heat otherwise lost in ice bank and chiller
systems |
SIZES IN MILLIMETRES AND INCHES
(not including side-header tank)
|
CAPACITY BASE HEIGHT
110 litres 610
x 610mm 610mm
137 610
x 610 762
182 610
x 610 915
228 610
x 610 1067
273 610
x 610 1220
319 686
x 686 1093
364 686
x 686 1220
455 813
x 813 1143
546 890
x 890 1270
615 927
x 927 1270
683 966
x 966 1270
900 1194
x 1194 1270
add 160mm to width for version with side mounted header tank |
CAPACITY BASE HEIGHT
24 gallons 24
x 24 ins 24
ins
30 24
x 24 ins 30
ins
40 24
x 24 ins 36
ins
50 24
x 24 ins 42
ins
60 24
x 24 ins 48
ins
70 27
x 27 ins 43
ins
80 27
x 27 ins 48
ins
100 32
x 32 ins 45
ins
120 35
x 35 ins 50
ins
135 37
x 37 ins 50
ins
150 38
x 38 ins 50
ins
200 40
x 40 ins 50
ins
add 6.3" to width for version with side mounted header tank |
|
We can manufacture non standard
sizes to customer's exact requirements.
Heat Recovery
Models are available, using the temperature of the hot gas produced
by the dairy refrigeration system to pre-heat the water.
Water heaters
can be supplied with a variable level stainless steel float switch.
This allows the amount of water to be heated to be changed very
easily.
Dual outlets are recommended (standard on 80 gallons and above),
to take advantage of off-peak electricity.
Various types of controller are available, from simple ball-valve
to sophisticated electronic systems using timers, level controllers
and microcontrollers.
ESSENTIAL
INFORMATION - WATER HEATER INSTALLATION
Cotswold Water Heaters are fitted with back-mounting bars, but,
due to their weight when filled, under-support is also necessary.
Load-bearing stands for all models are available from Cotswold.
When heaters are installed in a loft, please ensure that adequate
support for a fully-filled tank is provided.
Our water heaters are normally gravity-fed, therefore the water
outlets should be above the water trough unless it is intended
to empty the water heater using the plant vacuum or a pump.
In hard water areas, it is essential that a scale preventer and a water strainer are fitted.
These help prevent scale forming inside the water solenoid valve
and around the heater element. The cost of these inexpensive
devices will soon be recovered from reduced electricity charges.
Claims under warranty for damage or failure caused by hard water
and/or installation of the equipment to an unssuitable water
pressure will not be accepted unless the use has taken sensible
precautions. If you are in doubt please speak to Cotswold or
your dealer.
IMPORTANT
The cold
water inlet is controlled by an electrically operated solenoid
valve suitable for water pressures of bewtween 0 and 150 PSI,
(0-10 bar). Should your water pressure not be within this range,
please ask at the time of ordering and we will supply a water
heater with an alternative valve suitable for the pressure specified. |
|
|
|
FLOOR STANDING WATER HEATER
WITH SIDE MOUNTED HEADER TANK

|
PROBLEM:
Your Hot water becomes
progressively less hot as the milking cycle progresses
CAUSE:
Cold water is being admitted
to the hot water tank as hot water leaves, and this cools the
remaining water
SOLUTION:
Do not admit any cold
water until all of the hot water is used. Only then should you
refill the tank and heat water for the next milking cycle.
COMPLETE
SOLUTION:
Invest in a newly-introduced
Cotswold Water Heater with side-mounted header tank The
header tank contains a ball-valve feed system with vacuum-operated
clamp valve cut-off. This prevents cold water entering the tank
whilst the plant vacuum pump is running (ie whilst milking is
in progress).
BENEFITS:
A complete tank of hot water is available, which will NOT be
cooled by incoming cold water until the plant vacuum is
turned off at the end of the milking .
OK - it's not entirely new,
but a Cotswold Water Heater:-
- is of all-stainless-steel
construction - (no residential-style copper cylinders)
- has heating elements of long
life "Incoloy" which will last for many years
- has a fully-insulated rectangular
tank, making best use of the space available
- utilises strong brass ball
valve, not plastic type
- utilises electronic control
to minimise electrical consumption
- is exceptional value, yet
costs no more than existing models
SIZE The side mounted header tank adds 160mm (6.3")
to the width of the standard or economy model to which it is
fitted.
Sizes of standard
and economy water heaters. |
|